Description
Dual Advantage of Hybrid PCU Su-Kam’s Solar Power Conditioning unit (PCU) is an integrated system consisting of a solar charge controller, inverter and a Grid charger. It provides the facility to charge the battery bank through either a Solar or Grid/DG set. The PCU continuously monitors the state of battery voltage, solar power output and the load. Due to constant usage of power, if the battery voltage goes below a set level, the PCU will automatically transfer the load to the Grid/DG power and also charge simultaneously. Once the batteries are charged to the preset level, the Su-Kam’s Solar Power Conditioning unit cuts off the Grid/DG Power from the system and restore it to feeding the loads from the battery bank while also returning to charging the battery from the available solar power. The PCU always gives preference to the solar power and will use Grid/DG power only when the solar power / battery charger is unable to meet the load requirement.
Brand=”Su-kam” Manufacture=”Su-kam Power Systems Limited” Model=”SuKam1kPCU”
Technical Specifications of 1KVA Solar PCU | |
INVERTER RATING | 1KVA |
PV CHARGE CONTROLLER RATING | 1kWp |
Model No. | 1K24 |
Type | Single Phase Power Conditioning Unit |
Technology | DSP Based PWM Technology |
Power device | IGBTs cum MOSFETs |
INVERTER | |
INPUT PARAMETERS | |
Nominal I/P DC Voltage | 24V |
Input DC Voltage Range | 22V-30V±0.4V |
Low Battery cut off | 22.6V ± 0.4V |
Inverter Restart time after low battery when mains is not available | Battery voltage should be=25;5V |
High Battery shutdown | NA |
No load Power Consumption with No load shutdown
enable |
Less than 10 W |
No load shutdown ON/OFF (Factory settable as per customer requirement) | If the load is <60W,Output 5sec. ON and 50sec OFF every cycle. |
OUTPUT PARAMETERS | |
Waveform & Regulation | Pure Sine Wave, 230V + 5% |
Frequency Regulation | 50Hz + 0.2Hz |
Efficiency (typical)at linear load | =85% |
Total Load | 1kVA @ .8PF |
Overload | 200% for 8seconds |
THD (Linear load) | =5% on linear load |
Crest Factor | =3:1 |
Power usage Priority | From Photovoltaic Array |
Grid power usage | Grid power connects to the load when battery voltage = 24/48/96/120/180 V ± 2% in SMB (Solar-Mains Battery) and =
23.4/45/90/112/168 V± 2% in SBM (Solar-Battery-Mains) mode. |
Transfer Time inverter to mains and vice-versa | Typical 15 msec. |
GRID CHARGER | |
Grid I/P Voltage Range | WW-175-285&NW-190-265±10V |
Charging Current | 13A±1A |
SOLAR CHARGE CONTROLLER | |
Type | Series Regulator Common Negative |
Maximum I/P PV Voltage | 25V Per 36cell Solar module |
Solar Array | Single Array |
Charging Current Imax. Peak | = 20! / = 40! |
Bulk Voltage | 28.8V±0.4V |
Adjustable Bulk Voltage | 26.5V-30V |
Transition from float to bulk | Below float level for a cumulative period of 1 hour |
Float Voltage | 27V±0.4V |
PROTECTION | |
Over Current, Battery over Charge Protection, PV/Battery Reverse Polarity, Reverse Current Flow, High Temperature | |
Automatic Charger Restart Time after High Current | 3.5 Minutes |
Cooling | Forced air |
DATA LOGGING AND MONITORING | |
PC Data logging | PC GUI based data monitoring and storage. |
OTHER SPECIFICATIONS | |
Visual messages (LCD) | PV Voltage, PV current, Battery
Voltage, Output Voltage, Load %, Overload, Charging Current, Battery Low/High, Short circuit |
IEC standard | for 6H24) ; IEC62093
IEC61683, IEC60068-2-1,2,14,30,31 (N/A |
Design service use | Indoor |
Operating Temp. | 0°C to + 55°C |
Storage Temp. | 0°C to + 55°C |
Acoustic Noise @ 1metre | < 60dB |
Relative Humidity | 0-95% Non-Condensing |
Size (WxDxH) ± 10mm | 245x450x356 |
Weight (approx. in Kg) ± 400gm | 23.6 |