Su-kam 500VA 24V MPPT based Solar charger Power Conditioning Unit(PCU)

Su-kam 500VA 24V MPPT based Solar charger Power Conditioning Unit(PCU)

  • MPPT based solar charger.
  • DSP based technology fr inverter.
  • PWM technology mains grid charger and inverter with bidirectional operation .
  • Pure Sinewave output with Low THD.
  • Pulse by pulse current limiting with auto reset resulting in efficient overload and short circuit protection.
  • DC Reverse polarity and battery deep discharge protection.
  • Inbuilt Galvanic isolation transformer Solar and grid charging current sharing for maximum solar usage.
  • Buffer for battery backup in emergency.
  • To buy – Please fill Product Enquiry form.
  • Quoted price is excluding tax & applicable in Delhi. For price in other cities, please fill the Product Enquiry form below.
  • Download Manual
Product Enquiry Compare
Sold By : Su-Kam SKU: SUPCU-500-MPPT Categories: , ,

Description

As solar power is scarce so its maximum utilization is of utmost priority. In ths Sukam 500VA 24V MPPT based Solar charger Power Conditioning Unit(PCU) product Sukam has integrated its high efficient MPPT based charge controller inside the PCU. The optimum efficiency of the Inverter section along with high efficient MPPT charge controller helps generate maximum power from the solar panels. This makes the whole solar systems give maximum output from the same systems.

Brand=”Su-kam”Manufacture=”Su-kam Power Systems Limited” Model=”SUPCU-500-MPPT” Price=”17825″

 

Model No. SUPCU-500-MPPT
Warranty 2 Years
Brand Su-Kam
In the box 1 x 500VA 24V MPPT Solar PCU,manual and warranty card
Solar Inverter Type Grid Assisted Inverter
Charge Controller Type MPPT

Product Specifications of Sukam 500VA 24V MPPT based Solar charger Power Conditioning Unit(PCU)

As solar power is scarce so its maximum utilization is of utmost priority. Su-Kam has integrated its high efficient MPPT based charge controller
inside the PCU. The optimum efficiency of the Inverter section along with high efficient MPPT charge controller helps generate maximum power
from the solar panels. This makes the whole solar systems give maximum output from the same systems

Working of Solar PCU

– When solar energy is sufficient then total o/p load will operate on solar through MPPT and Inverter. Excess solar power will charge batteries
– When solar energy is weak then Inverter is taking DC source from solar & balance from batteries
– When batteries reach 75% discharge level the o/p load is shifted to grid
– After shifting load to grid (bypass) the batteries are charged from solar energy and if solar energy is not sufficient to charge the batteries, then
remaining DC power is taken from gird charges (Inverter is acting as a grid charger in reverse directions so the system is called a bidirectional PCU)
– Once the batteries are fully charged then load is shifted back to Inverter from grid
– During change over from Inverter to grid and if grid supply is not present then again load is shifted to Inverter to use buffer Battery backup.
– When grid returns during Inverter which is working on buffer Battery backup then the load is shifted to grid and batteries are charging through
solar or grid as per bi-directional logic

Features
– MPPT based solar charger
– DSP based technology for Inverter
– PWM technology mains grid charger and Inverter with
bidirectional operation
– Pure Sinewave output with Low THD

Electronic protection functions
– Pulse by pulse current limiting with auto reset resulting in
efficient overload and short circuit protection
– DC Reverse polarity and battery deep discharge protection
– Inbuilt Galvanic isolation transformer
– Solar and grid charging current sharing for maximum solar usage
– Buffer for battery backup in emergency

Displays
– LCD display for metering, I/P & O/P parameters
– Faults Display
– Remote Monitoring Software

TECHNICAL SPECIFICATIONS

Type MPPT BASED SOALR POWER CONDITIONING UNIT
Technology DSP Based MPPT Technology
Solar PCU Rating 500 VA
PV Charge Controller Rating 500Wp
Input Parameters
Nominal I/P DC Voltage 24V
Input DC Voltage Range 23.2-28.8V±0.2V
Low Battery cut off 23.2V±0.2V
High Battery shutdown 31V±2V
No load Power Consumption with No load shutdown enable Less than 10W
Output Parameters
Waveform & Regulation Pure Sine Wave 220V±2%
Efficiency (typical)at linear load ≥88%
Total Load >90%
Transfer Time inverter to mains & vice-versa Typical>20msec
GRID CHARGER
Grid I/P Voltage Range 150VAC-260VAC
Charging Current 13.0A±1A
SOLAR CHARGE CONTROLLER
Type  MPPT
Charging Current Imax. Peak 24.0A
Bulk Voltage 28.4V +Temp. Compensation
Adjustable Bulk Voltage (Adjustable 27.6V-28.8V) factory setting 28.8V
Float Voltage 27.4V+Temp. Compensation
Dimensions(W x H x D) 247x423x269 mm
Weight 17.5 kg

Additional information

Weight 20 kg

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.