Description
Compatible with DG and Wind mill. Changeover time less than 20 ms.Input power factor for grid charging near to unity.Hybrid Inverter Grid/Solar/Battery. Zero loss on bypass mode/ grid mode. Multi mode MPPT charger.Bi-directional PCU with Grid feed facility. MPPT based Solar battery Charger. Display with Solar KW and KWH meter and fault log. Modes available SGB/SBG/GFM/GSB/Inv. Auto bypass and manual bypass.Auto fault reset for non critical faults.SBG mode with buffer level selection facility 25/50/75.
Brand=”Enertech” Manufacture=”Enertech UPS Pvt Ltd” Model=”ENPCU1KVA-48VDC” Price=”Rs 40000.00″
MODEL | SUN MAGIC (1KVA) | |||||||||
INVERTER | 1KVA | |||||||||
DC Voltage | 48V | |||||||||
Output Voltage (Inverter Mode) | 230V AC ±2%, 1 Phase | |||||||||
Output Frequency (Free Running) | 50Hz ± 0.5% | |||||||||
Output Waveform | Pure Sine Wave | |||||||||
Peak Inverter Efficiency (Full Load) | >90% | |||||||||
Overload | 125% FOR 60 SEC, 150% FOR 5 SEC | |||||||||
Changeover Time (At Full Load) | <=20ms | |||||||||
Bypass Facility | Manual for Service | |||||||||
DC To AC Isolation | Transformer | |||||||||
BATTERY | ||||||||||
Nominal Battery Voltage | 48V DC | |||||||||
Grid Charging Current | 5V,10V,15V,20V Selectable | |||||||||
Input Power Factor (Grid Charging) | Near to Unity | |||||||||
Battery Charging Voltage | Selectable | |||||||||
INPUT | ||||||||||
Input Voltage Range | 170V to 260V (±5V), 1 Phase | |||||||||
DG Compatibility | Yes | |||||||||
Input Frequency Range | 50Hz ± 6% | |||||||||
SOLAR | ||||||||||
Charger Type | MPPT | |||||||||
Max PV Voltage (VOC) | 90V | |||||||||
Solar Working Range | 60V-90V | |||||||||
MPPT Modes Available | 2 ( Selectable) | |||||||||
Solar Charger Current Rating | KVA=KW as per rating | |||||||||
Panel Reverse Protection | YES | |||||||||
Solar Charger Efficiency | >94% | |||||||||
CONFIGURATION | ||||||||||
Modes Available | SBG/SGB/GSB/Grid Feed mode/Inv | |||||||||
Battery Buffer Setting | 25%/50%/75% | |||||||||
GRID Feed Mode | SELECTABLE | |||||||||
RESET | ||||||||||
Manual Fault Reset/Buzzer Reset | YES | |||||||||
Auto Reset | BATTERY Low and Overload | |||||||||
DISPLAY | ||||||||||
Input | Voltage, Current and Frequency | |||||||||
Output | Voltage, Current and Frequency | |||||||||
Battery | Voltage and %of Discharge | |||||||||
Solar | Voltage, Current, KW, KWh | |||||||||
Other | Current Status, Configuration, Fault Log | |||||||||
Power Dashboard | Grid KW, Load KW & Solar KW | |||||||||
INDICATIONS | ||||||||||
LED | Grid On, PV On, Grid Charger On, Inverter On,
Load On Mains,Load On Grid, Fault |
|||||||||
LCD | KVA Rating, Current Status, Input -Voltage/Current/Frequency,
Inverter –Voltage/Current, Output- Voltage/Current/Frequency, Solar-Panel Voltage /Current &KWH Rating, Battery-Voltage &Status ,Configuration |
|||||||||
ALARM | Audible For Fault And Warnings | |||||||||
ENCLOSURE | ||||||||||
Degree of Protection | Indoor | |||||||||
Cooling | Force Air Cool | |||||||||
Color | Siemens Grey | |||||||||
ENVIRONMENTAL | ||||||||||
Temperature Range (Operating) | 0°C to 40°C | |||||||||
Temperature Range (Storage) | -10°C to 60°C | |||||||||
Altitude (max) | 1000m | |||||||||
OPTIONAL @ Extra | Battery Reverse Indication
Panel Reverse Indication PV Side Surge Protection RS 232 Communication Port GSM Remote Monitoring Facility Wind Charger Connection Terminal Wind charge current Solar radiation (with external Pyranometer) Wind speed (with external anemometer) |
Reviews